110kV
Zinc-oxideMai Kamewa Surge
Gabaɗaya
Nau'in Zinc OxideMai Kamewa Surgeshine sabon ci gaba a kan-ƙarfin wutar lantarki don layin rarrabawa da na'urar tashar wutar lantarki. Haɗe tare da zinc oxide da sauran ƙarfe oxide azaman babban diski mai juyi, halayen volt-ampere da ƙarfin halin yanzu na discare mai tsayayya ya inganta sosai idan aka kwatanta da na al'ada nau'in SiC.
Ƙarƙashin ƙarfin wutar lantarki na yau da kullun, na yanzu ta wurin mai kamawa yana kusa da darajar micro-ampere kawai. Lokacin da mai kamawa ya sami ƙarin ƙarfin ƙarfin lantarki, faifan resistor tare da kyawawan halayen da ba na layi ba zai ƙara ƙarfin halin yanzu ta wurin mai kamawa zuwa amperes dubu da yawa nan take. Mai kamawa yana cikin halin gudanarwa sannan zai saki makamashin da ya wuce gona da iri zuwa ƙasa kuma ta haka yana kare rarraba wutar lantarki na na'urar watsawa daga tasirin wuce gona da iri.
Ayyukan Fasaha:
Ayyukan samfur sun dace da buƙatun fasaha na IEC60099-4, IEEE.C62.11.
Muhallin Aikace-aikace:
1. Yanayin zafin jiki: -40℃≤T≤40℃
2. Tsayi sama da matakin teku: ≤1000m
3. Max. Gudun iska: ≤ 35m/s
4. Girman girgizar ƙasa: ≤8
5. Mitar (tsarin AC): 50/60Hz
6. Wutar lantarki na mitar wutar lantarki na dogon lokaci ana amfani da shi ≤ Ci gaba da aiki ƙarfin lantarki Ya kamata a nuna ƙazanta mai nauyi kafin yin oda.
| Zinc-Oxide SurgeKama Maɓalli na Fasaha | |||||||
| Nau'in fitarwa na yanzu: 5KA | |||||||
| Nau'in MOA | An ƙididdige MOA | MCOV | 1/10µs m halin yanzu | 8/20µs walƙiya na halin yanzu | 30/60µs canza ƙarfin halin yanzu | 2ms rectangular halin yanzu juriya | 4/10µs babban ƙarfin halin yanzu juriya |
| kV (rms) | Ƙarfin kV | A | kA | ||||
| YH5W-3 | 3 | 2.55 | 11.3 | 9 | 8.90 | 150 | 65 |
| YH5W-6 | 6 | 5.10 | 22.6 | 18 | 16.8 | 150 | 65 |
| YH5W-9 | 9 | 7.65 | 33.7 | 27 | 23.8 | 150 | 65 |
| YH5W-10 | 10 | 8.40 | 36.0 | 30 | 26.4 | 150 | 65 |
| YH5W-1 才 | 11 | 9.40 | 40.0 | 33 | 30.0 | 150 | 65 |
| Saukewa: YH5W-12 | 12 | 10.2 | 42.2 | 36 | 31.7 | 150 | 65 |
| Saukewa: YH5W-15 | 15 | 12.7 | 51.0 | 45 | 38.5 | 150 | 65 |
| YH5W-18 | 18 | 15.3 | 61.5 | 54 | 46.5 | 150 | 65 |
| Saukewa: YH5W-21 | 21 | 17.0 | 71.8 | 63 | 54.5 | 150 | 65 |
| Saukewa: YH5W-24 | 24 | 19.5 | 82.0 | 72 | 62.6 | 150 | 65 |
| Saukewa: YH5W-27 | 27 | 22.0 | 92.0 | 81 | 69.8 | 150 | 65 |
| YH5W-30 | 30 | 24.4 | 102 | 90 | 79.0 | 150 | 65 |
| YH5W-33 | 33 | 27.5 | 112 | 99 | 86.7 | 150 | 65 |
| Saukewa: YH5W-36 | 36 | 29.0 | 117 | 103 | 92.4 | 150 | 65 |
| Saukewa: YH5W-39 | 39 | 31.5 | 123 | 108 | 94.0 | 150 | 65 |
| Saukewa: YH5W-42 | 42 | 34.0 | 126 | 111 | 101 | 150 | 65 |
| Saukewa: YH5W-45 | 45 | 36.5 | 128 | 119 | 105 | 150 | 65 |
| YH5W-48 | 48 | 39.0 | 139 | 127 | 110 | 150 | 65 |
| Saukewa: YH5W-51 | 51 | 40.8 | 151 | 134 | 115 | 150 | 65 |
| YH5W-54 | 54 | 42.0 | 160 | 143 | 119 | 150 | 65 |
| YH5W-60 | 60 | 48.0 | 178 | 159 | 132 | 150 | 65 |
| YH5W-66 | 66 | 53.0 | 196 | 175 | 145 | 150 | 65 |
| YH5W-69 | 69 | 55.2 | 205 | 183 | 152 | 150 | 65 |
| Maɓalli na Fasalolin Fasaha Polymeric Ƙwararrun Gidaje (Wahaƙiya) Mai kama | |||||||
| Nau'in fitarwa na yanzu: 10KA | |||||||
| Nau'in MOA | An ƙididdige MOA | MCOV | 1/10µs m halin yanzu | 8/20µs walƙiya na halin yanzu | 30/60µs canza ƙarfin halin yanzu | 2ms rectangular halin yanzu juriya | 4/10µs babban ƙarfin halin yanzu juriya |
| kV (rms) | Ƙarfin kV | A | kA | ||||
| YH10W-3 | 3 | 2.55 | 10.3 | 8.40 | 7.70 | 250 | 100 |
| YH10W-6 | 6 | 5.10 | 20.5 | 16.7 | 15.4 | 250 | 100 |
| YH10W-9 | 9 | 7.65 | 31.0 | 25.0 | 23.1 | 250 | 100 |
| YH10W-10 | 10 | 8.40 | 33.0 | 27.4 | 27.0 | 250 | 100 |
| YH10W-11 | 11 | 9.40 | 36.4 | 30.4 | 30.0 | 250 | 100 |
| YH10W-12 | 12 | 10.2 | 38.5 | 33.3 | 30.8 | 250 | 100 |
| YH10W-15 | 15 | 12.7 | 46.5 | 41.4 | 38.5 | 250 | 100 |
| YH10W-18 | 18 | 15.3 | 56.0 | 49.8 | 46.2 | 250 | 100 |
| Saukewa: YH10W-21 | 21 | 17.0 | 65.5 | 57.0 | 53.9 | 250 | 100 |
| YH10W-24 | 24 | 19.5 | 75.0 | 65.0 | 61.6 | 250 | 100 |
| Saukewa: YH10W-27 | 27 | 22.0 | 84.0 | 74.0 | 69.3 | 250 | 100 |
| YH10W-30 | 30 | 24.4 | 93.0 | 82.0 | 76.5 | 250 | 100 |
| YH10W-33 | 33 | 27.5 | 101 | 90.0 | 84.7 | 250 | 100 |
| YH10W-36 | 36 | 29.0 | 112 | 98.0 | 92.4 | 250 | 100 |
| YH10W-39 | 39 | 31.5 | 117 | 103 | 94.0 | 250 | 100 |
| Saukewa: YH10W-42 | 42 | 34.0 | 126 | 111 | 101 | 250 | 100 |
| YH10W-45 | 45 | 36.5 | 128 | 119 | 105 | 250 | 100 |
| YH10W-48 | 48 | 39.0 | 139 | 127 | 110 | 250 | 100 |
| YH10W-51 | 51 | 40.8 | 151 | 134 | 115 | 250 | 100 |
| YH10W-54 | 54 | 42.0 | 160 | 143 | 119 | 250 | 100 |
| YH10W-60 | 60 | 48.0 | 178 | 159 | 132 | 400 | 100 |
| YH10W-66 | 66 | 53.0 | 196 | 175 | 145 | 400 | 100 |
| YH10W-69 | 49 | 55.2 | 205 | 183 | 152 | 400 | 100 |
| Saukewa: YH10W-72 | 72 | 57.0 | 214 | 191 | 158 | 400 | 100 |
| YH10W-75 | 75 | 60.0 | 223 | 199 | 165 | 400 | 100 |
| YH10W-84 | 84 | 68.0 | 244 | 218 | 181 | 600 | 100 |
| YH10W-90 | 90 | 70.0 | 249 | 234 | 184 | 600 | 100 |
| YH10W-96 | 96 | 76.0 | 265 | 247 | 201 | 600 | 100 |
| YH10W-108 | 108 | 84.0 | 298 | 273 | 222 | 600 | 100 |
| YH10W-120 | 120 | 98.0 | 338 | 319 | 259 | 600 | 100 |
| Saukewa: YH10W-132 | 132 | 106 | 367 | 345 | 280 | 600 | 100 |
| YH10W-144 | 144 | 115 | 397 | 374 | 304 | 600 | 100 |
| YH10W-168 | 168 | 131 | 452 | 426 | 346 | 600 | 100 |
| Saukewa: YH10W-172 | 172 | 140 | 483 | 455 | 370 | 600 | 100 |
| YH10W-180 | 180 | 144 | 497 | 468 | 380 | 600 | 100 |