25kV 250A Madaidaiciyar Haɗi
Anhuang kwararre ne a madaidaicin mahaɗin, muna ba da madaidaiciyar madaidaiciyar maɗaukakiya.
Fasali:
Yana bayar da cikakkiyar kariya kuma za'a iya raba shi yayin haduwa da bushing ko toshe.
Point Ginin gwajin ƙarfin haɓaka don ƙayyade yanayin kewaye ko shigar da alamar nuna kuskure.
● Babu mafi ƙarancin buƙatar izinin lokaci.
● Hawan dutse na iya zama a tsaye, a kwance, ko kowane kusurwa a tsakanin.
Aikace-aikace:
• Don haɗin kebul na polymeric zuwa masu canza wuta, kayan sauyawa, motoci da sauran kayan aiki tare da mai haɗin keɓaɓɓen maɓallin raba.
● Don shigarwa na ciki da waje.
Voltage Tsarin lantarki har zuwa 24 kV.
● Ci gaba na yanzu 250 A (300 A obalodi na awanni 8).
Partic Bayanin kebul:
- Kebul na Polymeric (XLPE, EPR, da sauransu)
-Copper ko aluminum masu jagora
- Yin aikin karantarwa ko ƙarfe
-Girman jagora 25 ~ 120 mm2Kayan ciki:
Mai haɗa madaidaiciya
Pperarfe na jan ƙarfe ko Aluminum
Karfe kayan aiki
Share takarda
Silicone man shafawa
Shigar da takardar umarni
Takardar shaidar inganci
Tsarin Samfura
1 、 Gudanar da sanda: nau'in nau'in nau'in mai haɗawa zai iya zama jan ƙarfe ko bimatel.
2, SEMI-CONDUCTIVE INSERT: EPDM da aka gyara wanda ke gudanar da garkuwar roba yana sarrafa damuwar lantarki.
3, Tasirin Gwajin acarfafa: Mahimmin gwajin gwaji yana ba da hanya don bincika matsayin kewaye. EPDM da aka gyara wacce ke gudanar da hular roba tana rufe wurin gwajin lokacin da ba a amfani da shi.
4 R Taimako na 、warewa: Tsarin allo na waje da rufi suna ba da taimako na danniya na USB.
5, ranceofar Kebul: openingofar sized tana ba da damar tsangwama don kiyaye sikelin ruwa.
6 I GARKUWAR GASKIYA-SEMI: EPDM ta canza wanda ke gudanar da abokan roba
allon kebul don ci gaba da ci gaban allo da tabbatar da cewa taron yana cikin damar ƙasa.
7, Grounding Eye: Molded a cikin waje allo don dangane da wani earthing waya.
8, 、 M ed::::::
9 G Kullin Gwanin Kulle: Tanadi don zoben zoben uku-uku.
Bayani | Magana A'a. | Gudanar da giciyesashe (mm²) | Mikewa tsayerufi (mm) |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-25 | 24 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-35 | 35 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-50 | 50 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-70 | 70 | 19.8-23.5 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-95 | 95 | 23.1-27.1 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-120 | 120 | 23.1-27 .1 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-35 | 35 | 23.1-27 .1 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-50 | 50 | 23.1-27.1 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-70 | 70 | 23.6-26.4 |
25kV 250A Load break Straight Connector | AH ZTS-10 / 250-95 | 95 | 23.6-26.4 |
25kV 250A Madaidaiciyar Haɗi | AH ZTS-10 / 250-120 | 120 | 27.9-33.5 |